Instructions

                    Check the oil level is within the sight glass on the compressor body

                    Purge water from the water seperator unit and air filter unit

                    Connect cylinders to the hoses. Once all tanks are connected, switch on the cylinder valves and listen for and fix leaks. If
                        is missing or damaged then replace it. Spare tanks may be required to blank off spare hoses and these can remain switched off

                    A DIN tank must be filled by inserting the  and tightening with the 

                    Nitrox tanks must be filled using the
                        . This filter has a maximum flow rate that is substantially less than that of the compressor so if it is used other cylinders must also be filled at the same time. If in doubt refuse to fill the cylinder.

                    In line valves upstream of the tanks need to be opened, those downstream must be closed

                    The compressor will automatically switch off when 232 bar is reached, but in the event of a blown hose it will also switch off after a pre-determined time which is set by the timer on the wall. It is rated at 10cfm and so should lift 12 10l cylinders from 50bar to 232 bar in an hr and a half.

                    Start the compressor and leave to fill