UBUC Maintenance Documentation

This club exists to provide for its members facilities, opportunity and training for underwater exploration, science, and sport.

Back To Contents

Static Compressor is currently decomissioned

Edit this item

Other Attributes

Part Attributes Applicable Procedures
Main
  • manufacturer = William and James
  • model = Trident 201
  • newvalue = 7140
  • serial = 787
  • status = decomissioned
  • year = 1977
  • Water Seperator
    • manufacturer = midland
    • model = L0439
    • year = 2003
  • Filter
    • manufacturer = midland
    • model = LC 0320
    • year = 2003
Record
Complete
Difficulty Procedure Last Compleated Interval (Months) Estimated Cost
Static Use
Breathing Air Test 2012-06-14 3 50
Manage Static Filter 2015-10-07 4 50
Safety Inspection 12 420
Static Service 2012-06-14 24 300
Static Filters Test 2011-02-04 60 240
Non-diving oxygen cylinder testing 60
WS Renewal 2003-01-01 120 720
Filter Renewal 2003-01-01 240 1050

References

Logs

Add new log entry

Date Member Supplier Cost Comment Type Comment
2015-10-20 Chris Bainbridge Condition: decomissioned
2015-10-07 Daniel Chaney Midland Diving 47.00 Procedure: Manage Static Filter Filter Replaced at 2297. New filter needed at 2337
2015-08-12 Tim Walsh Current logged hrs=2294
2015-08-12 UBUC Daemon 1540.00 Condition: broken Static Service;WS Renewal;Manage Static Fil.;Breathing Air Test;Safety Inspection; out of date
2014-11-08 Daniel Chaney Midland Diving 47.00 Procedure: Manage Static Filter Filter replaced at 2254. Next replacement needed at 2294.
2014-02-24 Dave Wilby Condition: damaged Needle valve at far end of manifold needs replacing. At some point it has been over tightened, meaning that it now doesn't seal well/permanently. The result of this is that on finishing a compression, cylinders can leak and if carelessly left overnight cylinders may empty completely. Unsure of supplier, could be called a blowdown needle valve? Have provided the link to a swagelok page with a similar looking valve.
2013-10-24 Daniel Chaney Option for replacementBauer PE 250 TE Compressor
2013-10-24 Daniel Chaney 7140.00 Condition: quote Quote for Bauer PE 250 TE Compressor=£7140
2013-09-23 Daniel Chaney Procedure: Manage Static Filter Currently compressor is at 2202 hours, 7 hours to next change
2013-05-10 Tim Walsh 6900.00 Condition: quote Current replacement cost option £6358.80+£500 fitting
2013-05-10 Tim Walsh 9000.00 Condition: quote Current replacement cost option Silent 18 £8,500.00+£500 fitting
2013-03-19 Holly Vint Procedure: Manage Static Filter Filter replaced by Holly, current hours=2169 next change due at 2209 hours
2012-06-14 Holly Vint Central Compressors Procedure: Breathing Air Test Air Purity Test
2012-06-14 Holly Vint Central Compressors Procedure: Static Service Compressor Serviced
2012-06-14 Tim Walsh 500.00 Condition: niggle Procedure: Static Service Compressor out of Service
2011-02-04 Tim Walsh Central Compressors Procedure: Static Filters Test Hydro Test
2008-09-01 Tim Walsh Central Compressors Procedure: Static Filters Test Hydro Test
2003-01-01 Tim Walsh Procedure: WS Renewal Water Seperator renewed
2003-01-01 Tim Walsh Procedure: Filter Renewal Filter Unit renewed