UBUC Maintenance Documentation

This club exists to provide for its members facilities, opportunity and training for underwater exploration, science, and sport.

Back To Contents

Cylinder 02 is currently broken

Officers

Other Attributes

Part Attributes
Main
  • WC = 10L
  • currentvalue = 200
  • manufacturer = Faber
  • mass = 15kg
  • material = steel
  • repaircost = 50
  • serial = 00/9562/103
  • status = broken
  • year = 2000
Cylinder Operation
Cylinder Check 2016-01-10 6
Visual Inspection 2017-10-20 30 20
Hydraullic Test 2015-03-16 60 23.2

References

Log

Date Member Supplier Cost Comment
2018-03-01 Sam Walder 200.00 New value updated to: 200
2017-11-23 Sam Walder 50.00 Valve thread is damaged preventing use with DIN fittings. Could stick an insert in, but this is really bad. Suggest this needs the valve replacing.
2017-10-20 Sam Walder DM Scuba 21.00 Visual Inspection Performed by DMscuba
2017-10-20 Sam Walder DM Scuba Invoice for work performed
2017-10-07 UBUC Daemon 20.00 Visual Inspection; out of date
2016-01-10 Daniel Chaney Major Corrosion on base - need to keep an eye on this.
2015-03-16 Daniel Chaney DM Scuba 25.00 Hydro conducted by DM scuba
2015-03-16 Daniel Chaney Hydro always implies visual
2015-02-18 Tim Walsh 45.00 Out of visual test we will need to purchase both Vis and Hydro
2014-03-15 Tim Walsh Added QR Code label
2012-09-01 Holly Vint Hydraulic Test, next due Sep 2017
2012-09-01 Holly Vint Visual Inspection next due Mar 2015