Cylinder 23 is currently broken

Edit this item

Other Attributes

Part Attributes Applicable Procedures
Main
  • WC = 10L
  • manufacturer = Faber
  • mass = 15kg
  • material = steel
  • newvalue = 200
  • repaircost = 43.2
  • serial = 01/419/095
  • status = broken
  • year = 2001
Record
Complete
Difficulty Procedure Last Compleated Interval (Months) Estimated Cost
Cylinder Operation
Cylinder Check 2016-01-10 6
Visual Inspection 2020-09-07 30 20
Hydraullic Test 2018-03-30 60 23.2
Non-diving oxygen cylinder testing 60

References

Logs

Add new log entry

Date Member Supplier Cost Comment Type Comment
2023-04-01 UBUC Daemon 43.20 Condition: broken Visual Inspection; Hydraullic Test; out of date
2020-09-07 Greg Quick Condition: working Procedure: Visual Inspection Visual at Bristol Channel Divers
2018-03-30 Sam Walder Bristol Channel Divers Condition: working Procedure: Visual Inspection Visual inspection performed with hydro test
2018-03-30 Sam Walder Bristol Channel Divers Condition: working Procedure: Hydraullic Test Hydro test completed with BCD
2016-01-10 Daniel Chaney Procedure: Cylinder Check Surface scratches noted
2015-11-29 Daniel Chaney DM Scuba 21.00 Condition: working Procedure: Visual Inspection Visual Inspection Complete
2015-11-01 UBUC Daemon 20.00 Condition: broken Visual Inspection; out of date
2014-03-15 Tim Walsh Added QR Code label
2013-04-07 Tim Walsh 200.00 Condition: quote Current new replacement cost=£200
2013-04-01 Holly Vint Condition: working Procedure: Visual Inspection Visual Inspection next due Oct 2015
2013-04-01 Holly Vint Condition: working Procedure: Hydraullic Test Hydraulic Test next due Apr 2018