UBUC Maintenance Documentation

This club exists to provide for its members facilities, opportunity and training for underwater exploration, science, and sport.

Back To Contents

Cylinder 94 is currently broken

Edit this item

Other Attributes

Part Attributes Applicable Procedures
Main
  • WC = 12L
  • currentvalue = 200
  • manufacturer = Beaver
  • mass = 14.1kg
  • material = steel
  • repaircost = 33
  • serial = TGP098 UT
  • status = broken
  • year = 2007
Record
Complete
Difficulty Procedure Last Compleated Interval (Months) Estimated Cost
Cylinder Operation
Cylinder Check 6
O2 Clean 15 13
Visual Inspection 2019-10-01 30 20
Hydraullic Test 2019-10-01 60 23.2
Non-diving oxygen cylinder testing 60

References

Logs

Add new log entry

Date Member Supplier Cost Comment Type Comment
2022-05-01 UBUC Daemon 33.00 Condition: broken O2 Clean; Visual Inspection; out of date
2019-10-01 Greg Quick Bristol Channel Divers Procedure: Hydraullic Test Hydro based on stamp, no paperwork found
2019-10-01 Greg Quick Bristol Channel Divers Procedure: Visual Inspection Visual with hydro
2018-03-01 Sam Walder 200.00 Condition: valuation New value updated to: 200
2018-02-22 UBUC Daemon 13.00 Condition: damaged O2 Clean; out of date
2018-02-08 Sam Walder 80.95 Condition: working Cylinder purchased from Graham Howell
2017-01-01 Sam Walder Condition: working Procedure: Visual Inspection Inferred test date
2014-07-01 Sam Walder Condition: working Procedure: Hydraullic Test Inferred hydro test date