UBUC Maintenance Documentation

This club exists to provide for its members facilities, opportunity and training for underwater exploration, science, and sport.

Back To Contents

Regulator 11 is currently damaged

Edit this item

Other Attributes

Part Attributes Applicable Procedures
Main
  • DV = ATX40
  • currentvalue = 360
  • manufacturer = Apeks
  • mass = 2.5kg
  • repaircost = 85
  • serial = 10064646
  • stStage = DS4
  • status = damaged
  • year = 2010
Record
Complete
Difficulty Procedure Last Compleated Interval (Months) Estimated Cost
Regulator Use
Regulator Check 2015-09-14 6
Regulator Service 2020-10-10 12 85
Non-diving oxygen cylinder testing 60

References

Logs

Add new log entry

Date Member Supplier Cost Comment Type Comment
2021-11-01 UBUC Daemon 85.00 Condition: damaged Regulator Service; out of date
2020-11-19 Greg Quick Currently has wrong QR code sticker (Regulator 13's)
2020-11-19 Greg Quick Condition: niggle Wrong QR code
2020-10-10 Greg Quick Bristol Channel Divers 90.00 Condition: working Procedure: Regulator Service Serviced
2018-03-01 Sam Walder 360.00 Condition: valuation New value updated to: 360
2017-11-09 UBUC Daemon 85.00 Condition: damaged Regulator Service; out of date
2016-10-16 Daniel Chaney Condition: working Procedure: Regulator Service Regulator servicing complete
2015-11-05 Daniel Chaney Bristol Channel Divers Condition: working Procedure: Regulator Service SERVICE: Condition: Good, I.P: 9.5bar, Parts Replaced: None
2015-11-05 Sam Walder Bristol Channel Divers Condition: working Procedure: Regulator Service Aparently this one got serviced twice!
2015-09-14 Hayley Procedure: Regulator Check
2014-10-28 Dan Chaney JR Services 80.07 Condition: working Procedure: Regulator Service Serviced
2014-10-03 Daniel Chaney Condition: broken Procedure: Regulator Check Octopus freeflowing on purge and primary 2nd stage freeflowing when tilted upwards underwater.
2014-09-24 Daniel Chaney Condition: damaged Octopus free flowing on purge
2014-03-15 Tim Walsh Added QR Code label
2014-02-02 Daniel Chaney JR Services 77.00 Condition: working Procedure: Regulator Service Regulator Serviced
2013-01-11 Holly Vint 70.00 Condition: damaged Out of Service, pool use only