Regulator 13 is currently broken

Officers

Other Attributes

Part Attributes
Main
  • DV = R190
  • currentvalue = 270
  • manufacturer = Scubapro
  • mass = 2.5kg
  • serial = 5100507125
  • stStage = Mk2
  • status = broken
Regulator Use
Regulator Check 2015-09-14 6
Regulator Service 2013-01-11 12 85

References

Log

Date Member Supplier Cost Comment
2018-03-01 Sam Walder 270.00 New value updated to: 270
2018-01-30 Sam Walder Two mouthpieces missing
2018-01-17 Sam Walder Added a new pressure console after Apeks sent us a new 3
2017-11-22 Sam Walder This one is another broken apeks gague. I need to get in contact with Apeks about these. Upto 5 now.
2017-10-28 UBUC Daemon 85.00 Regulator Service; out of date
2017-10-25 Sam Walder Prablameo solvd
2017-09-17 Sam Walder Leaking from the hole in the first stage photgraphed in image
2015-09-14 Hayley
2014-09-24 Daniel Chaney HP hose fixed, out of test.
2014-03-15 Tim Walsh Added QR Code label
2013-10-26 Tim Walsh HP hose leaks
2013-03-19 Holly Vint Inspected by Holly and Niel, interstage pressure=9.5 bar
2013-01-11 Holly Vint JR Services 2*new mouthpieces, 3*hoses
2013-01-11 Holly Vint JR Services 118.98 Service + parts=£118.98