UBUC Maintenance Documentation

This club exists to provide for its members facilities, opportunity and training for underwater exploration, science, and sport.

Back To Contents

Regulator 46 is currently damaged

Edit this item

Other Attributes

Part Attributes Applicable Procedures
Main
  • DV = ATX40
  • currentvalue = 360
  • manufacturer = Apeks
  • mass = 2.5kg
  • repaircost = 85
  • serial = 1702 09031
  • stStage = DS4
  • status = damaged
  • year = 2016
Record
Complete
Difficulty Procedure Last Compleated Interval (Months) Estimated Cost
Regulator Use
Regulator Check 6
Regulator Service 2020-10-12 12 85
Non-diving oxygen cylinder testing 60

References

Logs

Add new log entry

Date Member Supplier Cost Comment Type Comment
2021-11-01 UBUC Daemon 85.00 Condition: damaged Regulator Service; out of date
2020-10-12 Greg Quick Bristol Channel Divers 90.00 Condition: working Procedure: Regulator Service
2018-03-01 Sam Walder 360.00 Condition: valuation New value updated to: 360
2017-09-13 Sam Walder Condition: broken Leaking from first stage and octopus
2017-09-06 UBUC Daemon 85.00 Condition: damaged Regulator Service; out of date