Cylinder 12 is currently broken

Officers

Other Attributes

Part Attributes
Main
  • WC = 12L
  • manufacturer = Faber
  • mass = 18kg
  • material = steel
  • owner = Ed Luff
  • repaircost = 20
  • serial = 11/0678/028
  • status = broken
  • year = 2011
Cylinder Operation
Cylinder Check 2016-01-10 6
O2 Clean 2017-10-20 15 13
Visual Inspection 2013-03-29 30 20
Hydraullic Test 2013-03-29 60 23.2

References

Log

Date Member Supplier Cost Comment
2017-11-09 UBUC Daemon 20.00 Visual Inspection; out of date
2017-10-20 Sam Walder DM Scuba 14.00 O2Clean Performed by DMscuba
2017-09-10 Sam Walder Realised that this one is owned by Ed Luff, added this to the discription
2016-01-10 Daniel Chaney Cylinder in good condition
2015-10-01 UBUC Daemon 33.00 O2 Clean;Visual Inspection; out of date
2014-09-24 Tim Walsh 13.00 Oxygen clean has lapsed, cylinder must not hold >40% O2
2013-03-29 Daniel Chaney JR Services Hydraulic Test
2013-03-29 Daniel Chaney JR Services Visual Inspection
2013-03-29 Daniel Chaney JR Services Visual Inspection