Cylinder 17 is currently broken

Edit this item

Other Attributes

Part Attributes Applicable Procedures
Main
  • WC = 12L
  • currentvalue = 170
  • manufacturer = Faber
  • mass = 18kg
  • material = steel
  • repaircost = 33
  • serial = 04/2003/165
  • status = broken
  • year = 2004
Record
Complete
Difficulty Procedure Last Compleated Interval (Months) Estimated Cost
Cylinder Operation
Cylinder Check 2016-01-10 6
O2 Clean 2017-10-20 15 13
Visual Inspection 2020-03-24 30 20
Hydraullic Test 2020-03-24 60 23.2
Non-diving oxygen cylinder testing 60

References

Logs

Add new log entry

Date Member Supplier Cost Comment Type Comment
2022-10-01 UBUC Daemon 33.00 Condition: broken O2 Clean; Visual Inspection; out of date
2020-03-24 Greg Quick Procedure: Hydraullic Test Hydro at South West Maritime Academy
2020-03-24 Greg Quick Procedure: Visual Inspection Visual with hydro
2018-03-01 Sam Walder 170.00 Condition: valuation New value updated to: 170
2018-02-16 Sam Walder Condition: damaged This tank was identified as an issue after the October service. The comment from inspection was: Dirty Valve. Minor rust specs inside tank
2017-12-10 Sam Walder Condition: damaged This cylinder was exposed to the compressor for its 3 day continuous run. See the report on the compressor log for details
2017-10-20 Sam Walder DM Scuba Condition: working Procedure: Visual Inspection Visual Inspection Performed by DMscuba
2017-10-20 Sam Walder DM Scuba 25.00 Condition: working Procedure: Hydraullic Test Hydro Test Performed by DMscuba
2017-10-20 Sam Walder DM Scuba 10.00 Condition: working Procedure: O2 Clean O2Clean Performed by DMscuba
2017-10-20 Sam Walder DM Scuba Condition: working Invoice for work performed
2016-01-10 Daniel Chaney Procedure: Cylinder Check Cylinder in good condition
2015-07-09 UBUC Daemon 36.20 Condition: broken O2 Clean;Hydraullic Test; out of date
2015-03-15 Daniel Chaney DM Scuba 21.00 Condition: working Procedure: Visual Inspection Visual Conducted by DM Scuba
2014-03-23 Tim Walsh 55.00 Condition: broken Estimate 55 to put back into service
2014-03-15 Tim Walsh Added QR Code label
2013-05-09 Tim Walsh Condition: broken Out of Test
2008-07-01 Daniel Chaney Condition: working Procedure: Hydraullic Test Hydraulic Test
2008-07-01 Daniel Chaney Condition: working Procedure: Visual Inspection Visual Inspection