Main
  • WC = 12.2L
  • manufacturer = Faber
  • mass = 18kg
  • material = steel
  • newvalue = 220
  • serial = 98/9899/110
  • status = decomissioned
  • year = 1998
Record
Complete
Difficulty Procedure Last Compleated Interval (Months) Estimated Cost
Cylinder Operation
Cylinder Check 2016-01-10 6
O2 Clean 2013-03-29 15 13
Visual Inspection 2015-11-29 30 20
Hydraullic Test 2013-03-29 60 23.2
Non-diving oxygen cylinder testing 60

References

Logs

Add new log entry

Date Member Supplier Cost Comment Type Comment
2018-01-15 Sam Walder Condition: decomissioned Cylinder was failed by Bristol Channel Divers due to sever external rust after inspection was performed due to compressor issues
2017-12-10 Sam Walder Condition: damaged This cylinder was exposed to the compressor for its 3 day continuous run. See the report on the compressor log for details
2016-01-10 Daniel Chaney Procedure: Cylinder Check Major corrosion noted - need to keep an eye on this
2015-11-29 Daniel Chaney DM Scuba 21.00 Condition: damaged Procedure: Visual Inspection Visual Inspection Complete
2015-10-01 UBUC Daemon 33.00 Condition: broken O2 Clean;Visual Inspection; out of date
2014-09-24 Tim Walsh 13.00 Condition: damaged Oxygen clean has lapsed, cylinder must not hold >40% O2
2014-03-15 Tim Walsh Added QR Code label
2013-04-07 Tim Walsh 220.00 Condition: quote Current new replacement cost=£220
2013-03-29 Daniel Chaney JR Services Condition: working Procedure: Hydraullic Test Hydraulic Test
2013-03-29 Daniel Chaney JR Services Condition: working Procedure: Visual Inspection Visual Inspection
2013-03-29 Daniel Chaney JR Services Condition: working Procedure: O2 Clean Visual Inspection
2013-02-01 Holly Vint Condition: working Procedure: Visual Inspection Visual Inspection, next due Aug 2015